Falso negativo con el uso del doppler transcraneal en el diagnóstico de la muerte encefálica / Negative false with the transcranial Doppler use in the brain death diagnosis
| Dublin Core | Elementos de metadatos PKP | Metadatos para el documento | |
| 1. | Título | Título del documento | Falso negativo con el uso del doppler transcraneal en el diagnóstico de la muerte encefálica / Negative false with the transcranial Doppler use in the brain death diagnosis |
| 2. | Creador/a | Nombre de autor/a, institución, país | Alexeis Planas Oñate; Hospital Universitario General Calixto Garcia; Cuba |
| 3. | Materia | Disciplina(s) | |
| 3. | Materia | Palabra/s clave | Doppler transcraneal; Falso negativo; Muerte encefálica; Diagnóstico / Transcranial doppler; Negative false; Brain death; Diagnosis |
| 4. | Descripción | Resumen | Introducción: el doppler transcraneal (DTC) es utilizado frecuentemente en el diagnóstico de la muerte encefálica (ME). El uso de esta técnica presenta algunas limitaciones, encontrándose en ocasiones casos falsos negativos. Métodos: se estudia paciente con trauma cráneo-encefálico (TCE) severo y hematoma subdural temporo-parietal por pérdida brusca de conciencia en el curso de una hemorragia intraparenquimatosa putaminal. Se realiza intervención quirúrgica, con craneotomía realizada en hemisferio izquierdo, a pesar de lo cual presenta una mala evolución. Es diagnosticado en ME realizándose dos evaluaciones clínicas positivas para la misma, con intervalo de 6 horas de separación. Luego de concluida cada evaluación se realizó DTC, explorando las arterias cerebrales del polígono de Willis; con un tercer DTC realizado 6 horas después de la segunda evaluación clínica. Resultados: el DTC mostró patrones de parada circulatoria cerebral en la arteria cerebral media (ACM) derecha y en la arteria basilar mantenidos en el tiempo; mientras que en la ACM izquierda correspondiente al lado de la craneotomía, persistían las velocidades de flujo sanguíneo cerebral, situación que se mantuvo con el decursar del tiempo. Conclusiones: paciente con diagnóstico clínico de ME, con DTC que mostró persistencia de velocidades de flujo sanguíneo en la ACM del hemisferio de la craneotomía realizada, a pesar de presentar parada circulatoria cerebral por DTC por más de 18 horas, en la ACM derecha y arteria basilar. Demostrándose la limitación del DTC en el diagnóstico de la ME en las grandes craneotomías. Abstract Introduction: The transcranial doppler (TCD) is frequently used in the diagnosis of brain death. This technique has limitations, findings in many situations false negative cases. Methods: we studied a patient with several brain trauma, and temporo-parietal subdural hematoma by acute loss of conscience in the course of a putaminal intraparenquimatose hemorrhage. A craniotomy surgery intervention in cerebral left hemisphere was realized immediately, but the patient begins with a bad evolution and was diagnosed in brain death. We realized two positive clinical evaluations with an interval of six hours between them, after that it was realized a transcranial doppler used for the exploration of the cerebral arteries of Willis circle; with a third TCD realized 6 hrs later of the second clinical evaluation. Results: TCD showed the existence of cerebral circulatory arrest in cerebral middle artery (CMA) right and basilar artery persistent in the time, while in CMA left, in the craniotomy hemisphere side, showed a persistent velocity flow pattern in full time. Conclusions: patient with brain death clinical diagnosis, the TCD showed a persistent velocity flow pattern in full time in CMA left, in hemisphere side with craniotomy, and existence of cerebral circulatory arrest in cerebral middle artery right and basilar artery, persistent for more than 18 hrs later. This study showed the TCD limitations in patients with diagnosis of brain death and craniotomy surgery. |
| 5. | Editorial | Institución organizadora, ubicación | Editorial Ciencias Médicas |
| 6. | Colaborador/a | Patrocinador(es) | |
| 7. | Fecha | (DD-MM-AAAA) | 2016-09-25 |
| 8. | Tipo | Estado y género | 150 |
| 8. | Tipo | Tipo | |
| 9. | Formato | Formato de archivo | PDF, HTML |
| 10. | Identificador | Identificador uniforme de recursos | http://www.revmie.sld.cu/index.php/mie/article/view/188 |
| 11. | Fuente | Título; vol., núm. (año) | Revista Cubana de Medicina Intensiva y Emergencias; Vol. 16, No. 1 (2017): enero-marzo |
| 12. | Idioma | Español=es | es |
| 13. | Relación | Archivos complementarios | |
| 14. | Cobertura | Localización geoespacial, periodo cronológico, muestra de investigación (sexo, edad, etc.) | |
| 15. | Derechos | Derechos de autor/a y permisos |
Copyright (c) |